15 KiB
next version: 3.0
Breaking Changes
- switched to C++11 compiler
- separated access level from circuit name
- introduced access control list and user authentication for access to certain messages
- added automatic check for updates (ebusd and configuration)
- use CSV header line for determining columns and picking multi-language columns by language preference
- a circuit name is now required for all message configurations
- raw logging allows logging of messages or each sent/received byte defaulting to messages
Bug Fixes
- corrected numeric condition formatting
- corrected reporting of CSV error position
- corrected last update time of write messages
- close log file on SIGHUP for better logrotate support
- only allow a single scan at the same time
- check allowed value range for base types during decoding
- ignore first seconds of data when calculating symbols per second
- exclude messages without name
- fix for potentially zero resolution
- fix for ebusd not answering scan request from another participant
- corrected missing update notification on master message part
- corrected grouping of JSON output by circuit
- corrected address conflict detection when in answer mode
- fixed potential memory leaks and misused iterator
Features
- added support for MQTT handling via libmosquitto (will be compiled in when library is available)
- allow empty ID in filename for circuit and suffix extraction
- use scan ID as fallback for default circuit name
- added U3N/U3R/S3N/S3R data types
- added another log facility "other"
- added support for using cmake in addition to autoconf
- added Docker support
- allow invalid (non-BCD) coded SW and HW fields when looking for scan config file
- added "auth" command and user/access information to "info" command output
- added user and secret arguments to HTTP port
- use ACL in read/write/find/scan commands
- added -a and -l options to "find" command
- added possibility to define different log level per area on command line and with "log" command
- added decode option to "grab" command presenting decoding hints for unknown messages
- added option to use different source address QQ to read/write/hex commands
- enhanced scan for individual slave
- wait for broadcast scan answers before doing individual scans
- enhanced SymbolString to be aware of master/slave and get rid of CRC (instead calculate while sending/receiving)
- allow unusually formatted MQTT topics
- allow TTQ/TTH types to use less than 8 bits
- added support for optional user-defined columns to config files
- added circuit-level attributes to config files for use in JSON
- added -N option to "read" command
2.4 (2016-12-17)
Bug Fixes
- fixed removed last byte in "hex" command answers
- corrected checking duplicates of chained messages
- fixed reading beyond message bounds
- corrected output precision with reciprocal divisor
- corrected caching of master-master messages
- corrected default dump file name to "/tmp/ebusd_dump.bin"
Features
- extended default definition in CSV to allow message name and comment prefix/suffix
- added automatic reconnect of device if signal loss is persistent and extended "info" result with number of reconnects
- extended "grab" command to allow selection of all or only unknown messages in grab result
- added error log entry when ebusd address conflicts with another participant
- extended BTI/HTI/BTM types to allow replacement value
- added condition name to logging of "!load" instructions and "info" result
- added "--lograwdatafile" and "--lograwdatasize" options logging received/sent bytes to a dedicated text file
- added TTQ base type
- added support for constant value fields
2.3 (2016-11-06)
Bug Fixes
- synchronously request a message if needed for loading "*.inc" files
- corrected derivation for TEM_P type
- allow chained messages to be polled
- removed CRC from slave answer in decode
Features
- no longer poll scan messages since those are expected not to change
- added more message counts to "info" result
- added uih circuit with bar chart containing yields to HTML interface
2.2 (2016-10-16)
Breaking Changes
- completely reworked base data types to allow user-defined types
- added first version of TEM specific data type
- allow inline rename of template reference
- removed "stop" command for enhanced security
- use broadcast ID messages for identification and automatic configuration file selection
Bug Fixes
- corrected extra separator in CSV style dump
- corrected BCD representation in JSON
- corrected serial close()
- fix for storing own prepared master data
- no longer show messages that did not receive data in "find" command
- check address argument for validity in "scan" command
- only use cached data if no input is necessary in "read" command
- fix for poll "continue" errors
- fix for checking command line arguments
- fix for DAY data type
- corrected checking of inline conditions
- escape special characters in string data types for JSON
- corrected dumping of value lists
Features
- allow running multiple ebusd instances by configuration file (/etc/default/ebusd on debian)
- set keepalive option on network device
- added hex option to "find" command
- added optional initial active scan address to "--scanconfig" option that allows initiating a single destination address scan, a full scan, or sending a broadcast ident message (this is now the default)
- added MIN datatype
- avoid output of unprintable characters in string data types
- split verbosity of "read" and "find" commands into 3 levels
- added "indexed" parameter for JSON
- allow non-exact values for truncated time types
2.1 (2016-05-05)
Breaking Changes
- added "hex" command for sending arbitrary hex data, disabled it by default (use "--enablehex" command line option), and limit "write -h" command to known messages only.
This increases security by avoiding unintended sending of arbitrary messages. - changed ebusd default address to 0x31 in order to avoid address conflicts with popular devices on the bus
- added "!load" instruction for CSV configuration files allowing conditional loading of single other CSV file
- added "!include" instruction for CSV configuration files in order to include other files
- added support for UDP connected devices
Bug fixes
- require "-c" in write command
- corrected duplicate messages check with condition
- corrected maximum values for BCD and HCD types
- corrected weekday calculation (for smaller systems mainly)
- corrected determination of field name uniqueness
- corrected JSON read of passive messages
Features
- allow CSV to contain empty lines (no field filled in)
- added shorter HCD and BCD data types
- added data type NTS (null terminated string)
- added EXP and EXR data types (exponential)
- added option for changing PID file
- allow using newlines within quoted fields in CSV
- added support for string based conditions and on-the-fly condition definition
- enhanced HTTP user interface
- increased default receive timeout to 25ms
- extract default circuit name from CSV file name
- automatically start grabbing all messages
- add circuit+message name of known messages to grab result
- added buffer for network devices and flush potentially buffered input when connecting
- added option for setting transfer latency and use default 10 ms for network device
2.0 (2016-01-06)
Breaking Changes
- automatic configuration file selection by querying device identification ("--scanconfig").
Previous configuration files are still usable, but only without the "--scanconfig" command line parameter to ebusd (unless the files are renamed).
This is now enabled by default in the init.d (or systemd) scripts to work with ebusd-2.x.x configuration files. - support for chained messages with fields covering more than one message ID
Bug fixes
- avoid multiple identical derived messages
- return "empty" for queries without result (e.g. grab result)
- fix for stopping main loop in rare cases
- fix for extracting default circuit name from CSV file name
- fix for using pselect
- fix for finishing active request when own master address reception timed out
- fix for some memory issues
- fix for closing serial device that is no tty
- fix for dumping message definition
- fix for cache invalidation
- fixes for answer mode
Features
- respond to broadcast "write" command with "done broadcast"
- prepared for full file check with overlapping names and message keys
- added replacement value for date/time types
- extended "info" command with seen addresses, scan state, and loaded CSV file
- improved CSV file check
- insert index suffix extracted from CSV file name when applying defaults (format "ZZ.CCCCC[.index].csv")
- added support for MACH architecture (Mac OS)
- use empty condition messagename for referencing scan message
- allow read and write message definitions having the same ID
- add hint to decoding problems in "read" and "write" if answer was retrieved successfully
- added script for converting "grab result" to CSV
- exclusively lock serial device to prevent simultaneous access by another process
- extended "-i" parameter of "find" command to accept further ID parts
- include decode problems instead of returning invalid JSON
- extended allowed message ID length and max STR and HEX length
- extended "grab" command with "all" option for grabbing all messages instead of only unknown
- allow float values being used for int types
- added big endian data type variants (UIR, SIR, FLR, ULR, SLR)
- use numeric value as fallback for value lists with unknown value association
- increased verbosity during scan
- increased default bus acquisition retries from 2 to 3
- use named objects for JSON fields instead of array with fallback to numbered
- exclude conditions from "find -f" command
- let ebusd answer to scan request (if started with "--answer")
- add special length '*' for consuming remaining input for some string types (IGN, STR, HEX)
Changed files
https://github.com/john30/ebusd/compare/v1.3.0...v2.0
1.3.0 (2015-10-24)
Breaking Changes
- started with a new git repository for working on 2.0 version (previous repository was renamed to ebusd1)
- added support for conditional message definitions based on other message values
Bug fixes
- fix for numeric parsing of empty string
- allow HTTP port query string keys without value
- fix for thread cleanup
- update last message update time when actively sending it
- trim CSV lines and fields
- corrected derivation of field name, comment and unit in templates
- check invalid divisor/values for string and value list based types
- fix for overriding destination address in read command
- fix for cached master data
Features
- new "read" option "-n" for retrieving name/value pairs in numeric form
- new "find" option "-e" for exactly matching name and optional circuit (ignoring case)
- new "find" option "-F" for listing messages in CSV format with selected columns only
- added numeric, verbose, and required options to JSON and use "null" for unset or replacement value
- allow static ".json" files being served by HTTP port
- allow passing raw value when writing name/value pairs
- enhanced static HTML user interface to dynamic
- added possibility to use a different name for referenced field template
- added data type HCD (for Ochsner)
- added base type TTH (truncated time with 30 minutes resolution)
- added base type VTM (reverse HTM)
- added log entry for scan completion
- automatically invalidate cached data of messages with same name+circuit (ignoring level)
- added "info" command
- added circuit and name to verbose "read" output
- added option to pass additional input data to "read" command
- added messages without dedicated destination and cached data decoding error to "find" result
- new "write" option "-d" for overriding destination address
- allow CSV file name to define default destination address and circuit name (format "ZZ.CCCCC.csv") and if present, concat default circuit name and security suffix (circuit name in CSV starting with "#")
Changed files
https://github.com/john30/ebusd/compare/v1.2.0...v1.3.0
1.2.0 (2015-05-25)
Bug fixes
- corrected missing newline in ebusctl
- avoid updating last message change time when only the querying master was modified
- notify running requests on device error
Features
- new command line option "--readonly" for read-only access to the bus
- added support for retrieving data as JSON and additional files via optional HTTP port
- added first version of static HTML user interface (to be extended to a dynamic one later)
- new "read" option "-h" for sending hex read messages
- new "read" option "-p PRIO" for setting the poll priority of a message
- update cache on hex read or write
Changed files
https://github.com/john30/ebusd/compare/v1.1.0...v1.2.0
1.1.0 (2015-03-28)
Bug fixes
- return passive messages returned in "read" regardless of their age
- corrected divisor for chains of derived number types
- corrected master number calculation (no influence on any behaviour)
- fixed signed char warning on some compilers
- corrected minimum lock count according to spec.
- differentiate between valid empty result and not found field name
- fixed scanning for messages in subdirectories for certain file systems (thanks to joltcoke)
- allow mixing references to base types and templates in message definition
- renamed "class" to "circuit" in commands and message definition
- fixed reading cached values
- extended max allowed data length to 25 (spec says 16)
Features
- new command line option "--dumpconfig" for dumping message configurations
- new "find" command option "-f" for retrieving message configurations in CSV format
- new "find" command option "-i PB" to filter messages on primary command byte
- extended "read" command "FIELD" argument with optional ".N" for retrieving the N''th field with that name
- new "write" command option "-c" for compatibility with "read" and "find"
- automatically detect number of masters on the bus and add to "state" command
- support reciprocal divisor
- cache symbols instead of formatted strings. this allows retrieval of individual fields and verbose read from cache
- removed valid CRCs from log and hex "write"
- shortened manufacturer names for "scan"
- allow specifying multiple destination addresses in message definition and defaults
- added Arch Linux PKGBUILD scripts (thanks to cogano)
- new "read" command option "-d ZZ" for overriding destination address (e.g. for manual scan)
- allow message definitions without any field
- added broadcast ident message (requests all masters to send their identification) and added read ident for manual scan
- added support for AUTO-SYN generation (experimental!)
- added "grab" command for collecting and reporting seen unknown messages
Changed files
https://github.com/john30/ebusd/compare/v1.0.0...v1.1.0
1.0.0 (2015-02-18)
Breaking Changes
This is the first version of the completely reworked ebusd since October 2014.
Bug fixes
A lot of problems were fixed, such as memory leaks and segmentation faults.
Features
The daemon is now fully aware of the eBUS protocol and future versions will also support addressing a running daemon as answering master/slave. The main new feature is a completely rewritten configuration file engine, which allows the use of templates and defaults and thus simplifies the configuration files a lot. On the client side, a lot of commands have been added, such as "listen" (automatically send changed values listened to or polled), "find", and "state".
Changed files
https://github.com/john30/ebusd/commits/master
Thanks to Roland Jax and other authors for all their work in previous versions!