2.5 KiB
2.5 KiB
| 1 | # type | class | cmd | comment | msg type | ZZ | PBSB | NN | D1D2D3 | elements | sub | part | position | datatype | factor | unit | valid | comment | sub | part | position | datatype | factor | unit | valid | comment | sub | part | position | datatype | factor | unit | valid | comment | sub | part | position | datatype | factor | unit | valid | comment |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | get | vpm3035w | Ntc1Sensor | Ntc1Sensor | MS | 0A | B509 | 3 | 0D0000 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 3 | get | vpm3035w | Ntc2Sensor | Ntc2Sensor | MS | 0A | B509 | 3 | 0D0100 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 4 | get | vpm3035w | Ntc3Sensor | Ntc3Sensor | MS | 0A | B509 | 3 | 0D0200 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 5 | get | vpm3035w | Vortex | Wirbel, Bypass? | MS | 0A | B509 | 3 | 0D0300 | 1 | - | sd | 2,1 | uin | - | hz | - | - | ||||||||||||||||||||||||
| 6 | get | vpm3035w | CircoPumpPower | Zirkulationspumpe Leistung | MS | 0A | B509 | 3 | 0D0400 | 1 | - | sd | 1 | uch | - | % | - | - | ||||||||||||||||||||||||
| 7 | get | vpm3035w | PumpDutyCycle | Pumpe Einschaltdauer | MS | 0A | B509 | 3 | 0D0500 | 1 | - | sd | 1 | uch | - | % | - | - | ||||||||||||||||||||||||
| 8 | get | vpm3035w | MixerPosition | Mischer Position max. 220 Schritte | MS | 0A | B509 | 3 | 0D0600 | 1 | - | sd | 2,1 | uin | - | - | - | - | ||||||||||||||||||||||||
| 9 | get | vpm3035w | ElectricHeater | Elektrische Zusatzheizung | MS | 0A | B509 | 3 | 0D0800 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 10 | get | vpm3035w | HeatDemand | Heizanforderung | MS | 0A | B509 | 3 | 0D0900 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 11 | get | vpm3035w | OperatingMode | Betriebsart | MS | 0A | B509 | 3 | 0D0A00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 12 | get | vpm3035w | TappingSetpointManual | Zapfsollwert manuell | MS | 0A | B509 | 3 | 0D0B00 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 13 | get | vpm3035w | TappingSetpointAuto | Zapfsollwert automatisch | MS | 0A | B509 | 3 | 0D0C00 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 14 | get | vpm3035w | TappingSetpointActual | Zapfsollwert aktuell | MS | 0A | B509 | 3 | 0D0E00 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 15 | get | vpm3035w | LegionellaProtectionDay | Legionellenfunktion Wochentag | MS | 0A | B509 | 3 | 0D1000 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 16 | get | vpm3035w | LegionellaProtectionTime | Legionellenfunktion Zeitpunkt | MS | 0A | B509 | 3 | 0D1100 | 1 | - | sd | 3,2,1 | hti | - | - | - | - | ||||||||||||||||||||||||
| 17 | get | vpm3035w | StartParty | Modus Party | MS | 0A | B509 | 3 | 0D1200 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 18 | get | vpm3035w | StartHoliday | Modus Urlaub | MS | 0A | B509 | 3 | 0D1300 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 19 | get | vpm3035w | FlowRate | Volumenstrom | MS | 0A | B509 | 3 | 0D4600 | 1 | - | sd | 1,2 | d2c | 1.0 | l/min | - | - | ||||||||||||||||||||||||
| 20 | get | vpm3035w | VPMType | 1=VPM20/25 2=VPM30/35 | MS | 0A | B509 | 3 | 0D4B00 | 1 | - | sd | 1 | uch | - | - | - | - |