# Configuration file for ebusd MQTT integration with Home Assistant (https://www.home-assistant.io/).
|
|
|
|
# Use this file with ebusd in MQTT JSON mode to have many seen messages automatically appear on HA. This is achieved by
|
|
# using the MQTT Discovery feature of Home Assistant (see https://www.home-assistant.io/docs/mqtt/discovery/).
|
|
# The commandline options to ebusd should contain e.g.:
|
|
# --mqttport=1883 --mqttjson --mqttint=/etc/ebusd/mqtt-hassio.cfg
|
|
|
|
|
|
# This file allows flexible construction of MQTT topics and payloads depending on message and field definitions as well
|
|
# as global status topics.
|
|
# It is a set of named variables (or constants) with the name on the left of an equal sign and the value on the right,
|
|
# where only the value is allowed to contain references to other variables.
|
|
# A reference to a variable is escaped by a leading "%" character in front of the variable name consisting of only
|
|
# alphabetic characters or the underscore. A double percent character "%%" is replaced by a single "%" in the value.
|
|
# Curly braces may be used to separate a variable explicitly from the rest, e.g. as "%{version}" instead of "%version".
|
|
# Every variable without an underscore in the name is automatically made available as well with an uppercase name and a
|
|
# normalized value composed of only alphanumeric characters or underscore (i.e. suitable for being part of a topic).
|
|
# When using "?=" instead of only the equal sign in a variable definition, the variable value is set to empty when one
|
|
# of the variables referred to is empty or missing.
|
|
|
|
# The variable replacements are constructed for each message and/or field (depending on whether the topic is field
|
|
# specific or not) in the following order:
|
|
|
|
# 1. predefined constants from ebusd, i.e.
|
|
# %version the ebusd version number.
|
|
# %prefix the invariable prefix part of the "--mqtttopic" configuration option, defaults to "ebusd/".
|
|
# %prefixn the same as %prefix but without trailing slashes or underscores.
|
|
|
|
# 2. variables referring to constants only (directly or indirectly).
|
|
|
|
# 3. circuit and message specific variables:
|
|
# %circuit the circuit name.
|
|
# %name the message name.
|
|
# %priority the message poll priority (or 0).
|
|
# %level the message access level (or empty).
|
|
# %messagecomment the message comment.
|
|
# %direction the message direction ("r", "w", "u", or "uw").
|
|
# %topic the message update topic built from the mqtttopic configuration option (only if the topic is not field
|
|
# specific) and/or the %topic variable defined here.
|
|
|
|
# 4. the direction mapped from variables named "direction_map-%direction" with the actual direction in the suffix.
|
|
# Available as "%direction_map".
|
|
|
|
# 5. the field type mapped from variables named "type_map-%direction-%type" or "type_map-%type" as fallback with the
|
|
# field type and the optional direction in the suffix. The variable including the direction is evaluated first and
|
|
# if it is missing or the result is empty, the variable excluding the direction is used instead.
|
|
# This is also an implicit field type filter as missing or empty mappings are not published at all.
|
|
# Available as "%type_map".
|
|
|
|
# 6. other field specific variables for each field (only once for each message if the topic is field specific):
|
|
# %index the numeric field index (excluding ignored fields).
|
|
# %field the field name and key for JSON objects (equals the field index if no name is defined or the names are not
|
|
# unique in the message).
|
|
# %fieldname the field name (and nothing else like in %field, might be empty though!)
|
|
# %type the field type (one of "number", "list", "string", "date", "time", or "datetime").
|
|
# %basetype the base data type ID (e.g. "UCH").
|
|
# %comment the field comment (if any).
|
|
# %unit the field unit (if any).
|
|
# %min, %max, and %step the minimum/maximum possible value and step value for number fields.
|
|
# %topic the field (or message) update topic built from the mqtttopic configuration option and/or the %topic variable
|
|
# defined here.
|
|
|
|
# 7. optional field type switch in "%type_switch" using the value of the variable named "type_switch-by" and matching it
|
|
# against the value lines of the variable named "type_switch-%type" with the field type in the suffix.
|
|
# The value of such a variable needs to be a constant list of string pairs with one pair per line. Each pair is
|
|
# separated by "=" and the left part is the value set to the "type_switch" variable when the wildcard pattern in the
|
|
# right part matches the value of the "type_switch-by" value. The list is traversed from top to bottom with the
|
|
# first match stopping the evaluation. Optionally, "type_switch-names" can be used to define a list of variable
|
|
# names to be set in addition to the "type_switch" variable, in which case a list of variable names (comma
|
|
# separated) is expected as "type_switch-names" value and the appropriate values to set on the left side of each
|
|
# match list entry.
|
|
# Available as "%type_switch" and optionally by the set of fields as defined in "%type_switch-names".
|
|
|
|
# 8. optional field type part mapping in "%type_part" for each field type in variables named "type_part-%type" with the
|
|
# field type in the suffix (or the value of the "type_part-by" variable).
|
|
|
|
# 9. if the %fields_payload variable is used, then it is set to the concatenation of all fields of the message:
|
|
# %field_payload is expected to build a single field payload.
|
|
# %field-separator is the separator placed between consecutive field payloads.
|
|
# %fields_payload is set to the concatenation of all fields of the message, separated by %field-separator.
|
|
|
|
# 10. %definition-topic, %definition-payload, and %definition-retain to build the message definition topic and payload
|
|
# and determine the retain value.
|
|
|
|
|
|
# Before constructing the variable replacements, the messages and fields can optionally be filtered in order to use
|
|
# certain message definitions only. All of these criteria are applied, so they are basically combined by "AND".
|
|
# Filters with a "partial match" mention in the documentation allow using a limited glob/regex inspired case insensitive
|
|
# matching with the following options:
|
|
# - "|" allows defining alternatives, e.g. "a|b" matches "but" as well as "all".
|
|
# - "^" matches the beginning of the input, e.g. "^al" matches "al" but not "hal".
|
|
# - "$" matches the end of the input, e.g. "al$" matches "hal" but not "all".
|
|
# - "*" matches a single arbitrary length wildcard part in the middle, e.g. "^a*l$" matches "all" but not "always".
|
|
|
|
# include only messages having data sent at least once (only checked for passive or read messages, not for active write)
|
|
# when set to 1. If set to >1, then all messages passing the other filter criteria (including active read messages) will
|
|
# automatically be set to have a poll priority of at most this value, so these are automatically being polled.
|
|
# HA integration: filtering only seen messages to avoid unnecessary "pollution" and auto-poll all matched messages
|
|
filter-seen = 5
|
|
# include only messages having a priority less than or equal to the specified value.
|
|
#filter-priority =
|
|
# include only messages having the specified circuit (partial match, alternatives and wildcard supported).
|
|
#filter-circuit =
|
|
# exclude messages having the specified circuit (partial match, alternatives and wildcard supported).
|
|
#filter-non-circuit =
|
|
# include only messages having the specified name (partial match, alternatives and wildcard supported).
|
|
# HA integration: filter to some useful names for monitoring the heating circuit
|
|
filter-name = status|temp|yield|count|energy|power|runtime|hours|starts|mode|curve|^load$|^party$|sensor
|
|
# exclude messages having the specified name (partial match, alternatives and wildcard supported).
|
|
#filter-non-name =
|
|
# include only messages having the specified level (partial match, alternatives and wildcard supported).
|
|
# Note: This is a filter on top of the messages already filtered implicitly for the ebusd "mqtt" user (if any).
|
|
# Note: Since the empty string matches all levels, an explicit check for empty string (with "^$") needs to be used for
|
|
# including only messages without a level.
|
|
filter-level = ^$
|
|
# include only messages having the specified direction ("r", "w", "u", or "uw". partial match, alternatives and wildcard supported).
|
|
# HA integration: writable messages excluded for now
|
|
filter-direction = r|u
|
|
# HA integration: for including writable messages, use this line or overwrite with '--mqttvar=filter-direction=r|u|^w'.
|
|
#filter-direction = r|u|^w
|
|
# include only fields having the specified name (partial match, alternatives and wildcard supported).
|
|
#filter-field =
|
|
# exclude fields having the specified name (partial match, alternatives and wildcard supported).
|
|
# HA integration: exclude the useless sensor ok/cutoff info from temperature sensor.
|
|
filter-non-field = ^sensor$
|
|
|
|
|
|
# HA integration: home assistant configuration topics prefix
|
|
haprefix = homeassistant
|
|
# HA integration: the area of all entities in home assistant
|
|
area = Heating
|
|
|
|
# HA integration: circuit specific part used as device entity for message definitions below
|
|
circuit_part = {
|
|
"identifiers":"%{PREFIX}_%CIRCUIT",
|
|
"manufacturer":"ebusd.eu",
|
|
"name":"%prefixn %circuit",
|
|
"via_device":"%PREFIXN",
|
|
"sw_version":"%version",
|
|
"suggested_area":"%area"
|
|
}
|
|
|
|
# the field type mapped from variables named "type_map-%direction-%type" or "type_map-%type" as fallback with the
|
|
# field type and the optional direction in the suffix. The variable including the direction is evaluated first and
|
|
# if it is missing or the result is empty, the variable excluding the direction is used instead.
|
|
# This is also an implicit field type filter as missing or empty mappings are not published at all.
|
|
type_map-number = number
|
|
type_map-list = string
|
|
# HA integration: skip string/date/time types completely
|
|
type_map-string =
|
|
type_map-date =
|
|
type_map-time =
|
|
type_map-datetime =
|
|
|
|
# field type switch designator, see below.
|
|
# HA integration: this is used to set several variable values depending on the field type, name, message, and field unit.
|
|
type_switch-by = %name%field,%unit
|
|
|
|
# field type switch variables names to use in addition to %type_switch in case of multiple keys (separated by comma).
|
|
# HA integration: var names for topic/class/state/sub values mapped from field type, name, message, and unit.
|
|
type_switch-names = type_topic,type_class,type_state,type_sub
|
|
|
|
# field type switch for each field type and optionally direction (between dash before the field type) available as
|
|
# %type_switch (as well as the variable names defined in "type_switch-names" if any).
|
|
# The value needs to be a constant list of string pairs with one pair per line. Each pair is separated by "=" and the
|
|
# left part is the value set to the type_switch variable (as well as the variable names defined in %type_switch-names)
|
|
# when the wildcard string in the right part matched the "type_switch-by" value. The list is traversed from top to
|
|
# bottom stopping at the first match. If direction specific definitions exist, these are traversed first. If no line
|
|
# matches at all, the variable(s) are set to the empty string.
|
|
# HA integration: the mapping list for (potentially) writable number entities by field type, name, message, and unit.
|
|
type_switch-w-number =
|
|
number,temperature, = temp|,°C$
|
|
number,power_factor, = power*%%
|
|
number,power, = power|,kW$|,W$
|
|
number,voltage, = volt|,V$
|
|
number,current, = current,|,A$
|
|
number,pressure, = bar$
|
|
number,gas, = gas*/min$
|
|
number,humidity, = humid*%%$
|
|
number,, = curve,
|
|
|
|
# HA integration: the mapping list for numeric sensor entities by field type, name, message, and unit.
|
|
type_switch-number =
|
|
sensor,temperature,measurement = temp|,°C$
|
|
sensor,power_factor,measurement = power*%%
|
|
sensor,power,measurement = power|,kW$|,W$
|
|
sensor,voltage,measurement = volt|,V$
|
|
sensor,current,measurement = current,|,A$
|
|
sensor,energy,total_increasing = energy|,Wh$
|
|
sensor,yield,total_increasing = total*,Wh$
|
|
sensor,,total_increasing = hours|,h$
|
|
sensor,,total_increasing = starts*,$
|
|
sensor,pressure,measurement = bar$
|
|
sensor,gas,measurement = gas*/min$
|
|
sensor,humidity,measurement = humid*%%$
|
|
sensor,, =
|
|
|
|
# HA integration: the mapping list for (potentially) writable binary switch entities by field type, name, message, and unit.
|
|
type_switch-w-list =
|
|
switch,, = onoff
|
|
switch,,,yesno = yesno
|
|
|
|
# HA integration: the mapping list for rather binary sensor entities by field type, name, message, and unit.
|
|
type_switch-list =
|
|
binary_sensor,,measurement = onoff
|
|
binary_sensor,,measurement,yesno = yesno
|
|
sensor,, =
|
|
|
|
# HA integration: currently unused mapping lists for non-numeric/non-binary entities.
|
|
#type_switch-string =
|
|
# sensor,, =
|
|
#type_switch-date =
|
|
# sensor,,measurement =
|
|
#type_switch-time =
|
|
# sensor,,measurement =
|
|
#type_switch-datetime =
|
|
# sensor, =
|
|
|
|
# HA integration: optional variable with the entity device class for numbers
|
|
type_class_number ?= ,
|
|
"device_class":"%type_class"
|
|
|
|
# HA integration: optional variable with the entity device class for sensors
|
|
type_class_sensor ?= ,
|
|
"device_class":"%type_class"
|
|
|
|
# HA integration: optional variable with the entity state class
|
|
state_class ?= ,
|
|
"state_class":"%type_state"
|
|
|
|
# HA integration: optional variable with the entity unit
|
|
unit_of_measurement ?= ,
|
|
"unit_of_measurement":"%unit"
|
|
|
|
# HA integration: optional variable with the minimum numeric value
|
|
min_number ?= ,
|
|
"min":%min
|
|
|
|
# HA integration: optional variable with the maximum numeric value
|
|
max_number ?= ,
|
|
"max":%max
|
|
|
|
# HA integration: optional variable with the numeric step value
|
|
step_number ?= ,
|
|
"step":%step
|
|
|
|
# field type part suffix to use instead of the field type itself, see below.
|
|
# HA integration: %type_part variable mapped from the mapped %type_topic and optional %type_sub
|
|
type_part-by = %type_topic%type_sub
|
|
|
|
# field type part mappings for each field type (or the "type_part-by" variable value) in the suffix (available as
|
|
# %type_part).
|
|
# HA integration: %type_part variable for number %type_topic
|
|
type_part-number = ,
|
|
"command_topic":"%topic/set"%min_number%max_number%step_number%unit_of_measurement%state_class%type_class_number
|
|
|
|
# HA integration: %type_part variable for sensor %type_topic
|
|
type_part-sensor = %unit_of_measurement%state_class%type_class_sensor
|
|
|
|
# HA integration: %type_part variable for switch %type_topic
|
|
type_part-switch = ,
|
|
"command_topic":"%topic/set",
|
|
"payload_on":"on",
|
|
"payload_off":"off"%state_class
|
|
|
|
type_part-switchyesno = ,
|
|
"command_topic":"%topic/set",
|
|
"payload_on":"yes",
|
|
"payload_off":"no"%state_class
|
|
|
|
# HA integration: %type_part variable for binary_sensor %type_topic
|
|
type_part-binary_sensor = ,
|
|
"payload_on":"on",
|
|
"payload_off":"off"%state_class
|
|
|
|
type_part-binary_sensoryesno = ,
|
|
"payload_on":"yes",
|
|
"payload_off":"no"%state_class
|
|
|
|
# the field specific part (evaluated after the message specific part).
|
|
# HA integration: set to the mapped %type_part from above
|
|
field_payload = %type_part
|
|
|
|
|
|
# the message definition config topic, payload, and retain setting.
|
|
# HA integration: the config topic for HA's MQTT discovery for the ebusd message definition found.
|
|
# set to conditionally to avoid incomplete configs.
|
|
definition-topic ?= %haprefix/%type_topic/%{TOPIC}_%FIELD/config
|
|
# HA integration: this is the config topic payload for HA's MQTT discovery.
|
|
definition-payload = {
|
|
"unique_id":"%{TOPIC}_%FIELD",
|
|
"name":"%prefixn %circuit %name %fieldname",
|
|
"device":%circuit_part,
|
|
"value_template":"{{value_json[\"%field\"].value}}",
|
|
"state_topic":"%topic"%field_payload
|
|
}
|
|
#definition-retain = 0
|
|
|
|
|
|
# the message value topic (if other than the default). If set here, it will be replaced by the "--mqtttopic"
|
|
# configuration option only if that one contains at least one variable. If the the "--mqtttopic" configuration option
|
|
# does not contain any variable, it is taken as prefix and can be used here as well.
|
|
# HA integration: use the prefix from --mqtttopic and non field specific topic for the actual data
|
|
topic = %prefix/%circuit/%name
|
|
|
|
|
|
# HA integration: global part used as device entity for the global config topics
|
|
global_device = {
|
|
"identifiers":"%PREFIXN",
|
|
"manufacturer":"ebusd.eu",
|
|
"name":"%prefixn",
|
|
"sw_version":"%version",
|
|
"suggested_area":"%area"
|
|
}
|
|
|
|
# HA integration: common prefix for global parts
|
|
global_prefix = {
|
|
"unique_id":"%TOPIC",
|
|
"device":%global_device,
|
|
"state_topic":"%topic",
|
|
"name":"%prefixn %name"
|
|
|
|
# HA integration: boolean suffix for global parts
|
|
global_boolean_suffix = ,
|
|
"state_class":"measurement",
|
|
"payload_on":"true",
|
|
"payload_off":"false"
|
|
}
|
|
|
|
# the common global config topic, payload, and retain setting (used by running, version, signal, uptime, updatecheck,
|
|
# and scan if not otherwise defined explicitly).
|
|
# HA integration: the config topic for HA's MQTT discovery for the ebusd global parts.
|
|
def_global-topic = %haprefix/sensor/%TOPIC/config
|
|
def_global-payload = %global_prefix,
|
|
"state_class":"measurement"
|
|
}
|
|
#def_global-retain = 0
|
|
|
|
# individual global running, version, signal, uptime, updatecheck, and scan config topic, payload, and retain setting.
|
|
def_global_running-topic = %haprefix/binary_sensor/%TOPIC/config
|
|
def_global_running-payload = %global_prefix,
|
|
"device_class":"running"%global_boolean_suffix
|
|
def_global_version-topic =
|
|
def_global_uptime-payload = %global_prefix,
|
|
"state_class":"total_increasing",
|
|
"unit_of_measurement":"s"
|
|
}
|
|
def_global_signal-topic = %haprefix/binary_sensor/%TOPIC/config
|
|
def_global_signal-payload = %global_prefix,
|
|
"device_class":"connectivity"%global_boolean_suffix
|
|
|
|
def_global_updatecheck-topic = %haprefix/update/%TOPIC/config
|
|
def_global_updatecheck-payload = %global_prefix,
|
|
"value_template":"{%% set my_vernum = value_json|truncate(255)|regex_replace(find=',.*| available|revision v|version v',replace='') %%}{%% set my_ver = {'installed_version':'%version','latest_version':my_vernum,'entity_picture':'https://ebusd.eu/logo-32x32.png','release_url':'https://github.com/john30/ebusd/releases/latest'} %%}{%% if my_vernum == '' %%}{%% set my_ver.latest_version = '%version' %%}{%% endif %%}{{ my_ver | tojson }}"
|
|
}
|
|
|
|
|
|
# optional secondary update check for the eBUS device (consuming the same topic though!)
|
|
def_global_updatecheck_device-topic = %haprefix/update/%{TOPIC}_device/config
|
|
def_global_updatecheck_device-payload = {
|
|
"unique_id":"%{TOPIC}_device",
|
|
"device":{
|
|
"identifiers":"%{PREFIXN}_device",
|
|
"manufacturer":"ebusd.eu",
|
|
"name":"%prefixn device",
|
|
"via_device":"%PREFIXN",
|
|
"suggested_area":"%area"
|
|
},
|
|
"state_topic":"%topic",
|
|
"name":"%prefixn %name",
|
|
"value_template":"{%% set my_vernum = value_json|truncate(255)|regex_replace(find='^[^,]*|, device firmware |,.*| available',replace='') %%}{%% set my_ver = {'installed_version':'old','latest_version':my_vernum,'entity_picture':'https://adapter.ebusd.eu/favicon.ico','release_url':'https://adapter.ebusd.eu/firmware/ChangeLog'} %%}{%% if my_vernum == '' %%}{%% set my_ver.installed_version = 'current' %%}{%% set my_ver.latest_version = '%version' %%}{%% endif %%}{{ my_ver | tojson }}"
|
|
}
|
|
|
|
# the topic and payload to listen to in order to republish all config messages.
|
|
# HA integration: force republish of all configs when HA goes down and comes up again.
|
|
config_restart-topic = %haprefix/status
|
|
config_restart-payload = online
|