13 KiB
13 KiB
| 1 | # type | class | cmd | comment | msg type | ZZ | PBSB | NN | D1D2D3 | elements | sub | part | position | datatype | factor | unit | valid | comment | sub | part | position | datatype | factor | unit | valid | comment | sub | part | position | datatype | factor | unit | valid | comment | sub | part | position | datatype | factor | unit | valid | comment |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 2 | get | vwx | BivalentTemp | Bivalenztemperatur | MS | 08 | B509 | 3 | 0D6500 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 3 | get | vwx | Bleeding | Entlüften | MS | 08 | B509 | 3 | 0D1300 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 4 | get | vwx | BrinePress | Druck Solekreis | MS | 08 | B509 | 3 | 0D1600 | 2 | press | sd | 1,2 | flt | 0.001 | bar | - | Druck | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 5 | get | vwx | BrinePressSwitch | Soledruckschalter | MS | 08 | B509 | 3 | 0D2600 | 1 | - | sd | 1,2 | sin | - | - | - | - | ||||||||||||||||||||||||
| 6 | get | vwx | BrinePumpCoolingRunTime | Kühlung Laufzeit Solepumpe | MS | 08 | B509 | 3 | 0D7D01 | 1 | - | sd | 1,2,3,4 | ulg | - | h | - | - | ||||||||||||||||||||||||
| 7 | get | vwx | BrinePumpPower | Solepumpe Leistung | MS | 08 | B509 | 3 | 0DAC01 | 1 | - | sd | 1 | uch | - | % | - | - | ||||||||||||||||||||||||
| 8 | get | vwx | BrinePumpPowerHeating | Solepumpe Leistung beim Heizen | MS | 08 | B509 | 3 | 0DAE01 | 1 | - | sd | 1 | uch | - | % | - | - | ||||||||||||||||||||||||
| 9 | get | vwx | BrinePumpPreRunTime | Vorlaufzeit Quellenpumpe | MS | 08 | B509 | 3 | 0D7600 | 1 | - | sd | 1,4 | ulg | - | min | - | - | ||||||||||||||||||||||||
| 10 | get | vwx | BrinePumpState | Solepumpe Status | MS | 08 | B509 | 3 | 0D1900 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 11 | get | vwx | BrinePumpState | Solepumpe Status | MS | 08 | B509 | 3 | 0DB801 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 12 | get | vwx | BrineTempInput | T3 Sole Temperatur Vorlauf – von Quelle | MS | 08 | B509 | 3 | 0D0F00 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 13 | get | vwx | BrineTempOutput | T8 Sole Temperatur Rücklauf – zur Quelle | MS | 08 | B509 | 3 | 0D0800 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 14 | get | vwx | CirculationPumpInput | Zirkulationspumpe Eingang | MS | 08 | B509 | 3 | 0D0B00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 15 | get | vwx | CirculationPumpPower | Zirkulationspumpe Leistung | MS | 23 | B509 | 3 | 0DE601 | 1 | - | sd | 1 | uch | - | % | - | - | ||||||||||||||||||||||||
| 16 | get | vwx | CirculationPumpState | Zirkulationspumpe Status | MS | 08 | B509 | 3 | 0D0C00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 17 | get | vwx | Code1 | Code 1 | MS | 08 | B509 | 3 | 0D9700 | 1 | - | sd | 1,2 | uin | - | - | - | - | ||||||||||||||||||||||||
| 18 | get | vwx | Code2 | Code 2 | MS | 08 | B509 | 3 | 0D9800 | 1 | - | sd | 1,2 | uin | - | - | - | - | ||||||||||||||||||||||||
| 19 | get | vwx | CodeValid | Code 1 und 2 gültig | MS | 08 | B509 | 3 | 0D2400 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 20 | get | vwx | CompressorStartsHotWater | Kompressor Starts Warmwasser | MS | 08 | B509 | 3 | 0DA800 | 1 | - | sd | 1,2,3,4 | ulg | - | - | - | - | ||||||||||||||||||||||||
| 21 | get | vwx | CompressorStartsHeating | Kompressor Starts Heizung | MS | 08 | B509 | 3 | 0DA900 | 1 | - | sd | 1,2,3,4 | ulg | - | - | - | - | ||||||||||||||||||||||||
| 22 | get | vwx | CompressorStarts | Kompressor Starts | MS | 08 | B509 | 3 | 0DAA00 | 1 | - | sd | 1,2,3,4 | ulg | - | - | - | - | ||||||||||||||||||||||||
| 23 | get | vwx | CompressorNumberStarts | Kompressor Starts pro Stunde | MS | 08 | B509 | 3 | 0D7400 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 24 | get | vwx | CompressorState | Kompressor Status | MS | 08 | B509 | 3 | 0D1D00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 25 | get | vwx | CompressorTempInput | T1 Kompressor Temperatur Eintritt | MS | 08 | B509 | 3 | 0D0200 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 26 | get | vwx | CompressorTempOutput | T2 Kompressor Temperatur Austritt | MS | 08 | B509 | 3 | 0D0400 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 27 | get | vwx | Date | Datum | MS | 08 | B509 | 3 | 0D2900 | 1 | - | sd | 1,2,3 | hda | - | - | - | - | ||||||||||||||||||||||||
| 28 | get | vwx | DeicingState | Enteisung Status | MS | 08 | B509 | 3 | 0DCE01 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 29 | get | vwx | DeicingWaitTime | Enteisung Wartezeit zur nächsten Enteisung | MS | 08 | B509 | 3 | 0D7000 | 1 | - | sd | 1,2,3,4 | ulg | - | h | - | - | ||||||||||||||||||||||||
| 30 | get | vwx | EvaporatorTemp | Verdampfer Temperatur | MS | 08 | B509 | 3 | 0D0500 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 31 | get | vwx | ExpansionValveInputTemp | TEV Temperatur Eintritt | MS | 08 | B509 | 3 | 0D0D00 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 32 | get | vwx | FlowTemp | VF2 Vorlauftemperatur IST | MS | 08 | B509 | 3 | 0D0300 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 33 | get | vwx | FlowTempIntern | T6 interne Vorlauftempertur IST | MS | 08 | B509 | 3 | 0D0900 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 34 | get | vwx | FrezzeProtectionTempMin | Einfrierschutz T81 | MS | 08 | B509 | 3 | 0D7A01 | 1 | - | sd | 1 | sch | - | °C | - | - | ||||||||||||||||||||||||
| 35 | get | vwx | HeatPumpState | Heizkreispumpe Status | MS | 08 | B509 | 3 | 0D1700 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 36 | get | vwx | HeatSystemPress | Heizanlagendruck | MS | 08 | B509 | 3 | 0D1200 | 2 | press | sd | 1,2 | flt | 0.001 | bar | - | Druck | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 37 | get | vwx | Hysteresis | Kompressor Hysterese | MS | 08 | B509 | 3 | 0D7D00 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 38 | get | vwx | InitialCurrentLimitation | Anlaufstrombegrenzung | MS | 08 | B509 | 3 | 0D3F00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 39 | get | vwx | Integral | Energieintegral | MS | 08 | B509 | 3 | 0D8000 | 1 | - | sd | 1,2 | sin | - | °min | - | - | ||||||||||||||||||||||||
| 40 | get | vwx | IntegralStartValue | Energieintegral Startwert | MS | 08 | B509 | 3 | 0D7C00 | 1 | - | sd | 1,2 | sin | - | °min | - | - | ||||||||||||||||||||||||
| 41 | get | vwx | MixerPosition | Mischer Position -100 – 100 | MS | 08 | B509 | 3 | 0D0E00 | 1 | - | sd | 1 | sch | - | - | - | - | ||||||||||||||||||||||||
| 42 | get | vwx | NoiseReductionFactor | Lautstärken Reduktion Faktor | MS | 08 | B509 | 3 | 0D2401 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 43 | get | vwx | NoiseReductionState | Lautstärken Reduktion Status | MS | 08 | B509 | 3 | 0DA901 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 44 | get | vwx | Overheating | Überhitzung | MS | 08 | B509 | 3 | 0D8D00 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 45 | get | vwx | PhaseOrder | Drehfeld Status | MS | 08 | B509 | 3 | 0D5701 | 1 | - | sd | 1,2 | sin | - | - | - | - | ||||||||||||||||||||||||
| 46 | get | vwx | PhaseState | Phasen Status | MS | 08 | B509 | 3 | 0D8800 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 47 | get | vwx | PowerCutOff | EVU Sperrzeit – Stromunterbrechung | MS | 08 | B509 | 3 | 0D1100 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 48 | get | vwx | PumpState | Pumpen Status | MS | 08 | B509 | 3 | 0D1800 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 49 | get | vwx | RetrurnTempMax | Heizkreis Rücklauftemperatur MAX | MS | 08 | B509 | 3 | 0D7300 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 50 | get | vwx | ReturnTempIntern | T5 interne Rücklauftempertur IST | MS | 08 | B509 | 3 | 0D0A00 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 51 | get | vwx | RunTime | Kompressor Laufzeit Summe | MS | 08 | B509 | 3 | 0D9A00 | 1 | - | sd | 1,2,3,4 | ulg | - | h | - | - | ||||||||||||||||||||||||
| 52 | get | vwx | RunTimeHeating | Kompressor Laufzeit Heizung | MS | 08 | B509 | 3 | 0D9B00 | 1 | - | sd | 1,2,3,4 | ulg | - | h | - | - | ||||||||||||||||||||||||
| 53 | get | vwx | RunTimeHotWater | Kompressor Laufzeit Warmwasser | MS | 08 | B509 | 3 | 0D9C00 | 1 | - | sd | 1,2,3,4 | ulg | - | h | - | - | ||||||||||||||||||||||||
| 54 | get | vwx | ServiceMode | Servicezeit | MS | 08 | B509 | 3 | 0D6600 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 55 | get | vwx | SoftwareState | Software Status | MS | 08 | B509 | 3 | 0DCF00 | 1 | - | sd | 1,2,3,4 | ulg | - | - | - | - | ||||||||||||||||||||||||
| 56 | get | vwx | SwitchValve | Umschaltventil Heizen = 0 / Warmwasser = 1 | MS | 08 | B509 | 3 | 0D1000 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 57 | get | vwx | TempOutside | Aussentemperatur | MS | 08 | B509 | 3 | 0D0600 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 58 | get | vwx | TempSpreadMax | Zulässige Temperaturspreizung T6 zu T7 | MS | 08 | B509 | 3 | 0D6E00 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 59 | get | vwx | Time | Uhrzeit | MS | 08 | B509 | 3 | 0D2800 | 1 | - | sd | 3,2,1 | hti | - | - | - | - | ||||||||||||||||||||||||
| 60 | get | vwx | Undercooling | Unterkühlung | MS | 08 | B509 | 3 | 0D8E00 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 61 | get | vwx | VaporPressHigh | Hochdruck Kältekreis | MS | 08 | B509 | 3 | 0D1400 | 2 | press | sd | 1,2 | flt | 0.001 | bar | - | Druck | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 62 | get | vwx | VaporPressLow | Niederdruck Kältekreis | MS | 08 | B509 | 3 | 0D1500 | 2 | press | sd | 1,2 | flt | 0.001 | bar | - | Druck | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 63 | get | vwx | VaporPressostate | Kältekreis Über/Unterdruck Sicherheitsabschaltung | MS | 08 | B509 | 3 | 0D2500 | 1 | - | sd | 1,2 | sin | - | - | - | - | ||||||||||||||||||||||||
| 64 | get | vwx | Weekday | Wochentag | MS | 08 | B509 | 3 | 0D2A00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 65 | get | vwx | YieldEnvironmentEnergy | Energieertrag Umgebung | MS | 08 | B509 | 3 | 0DBC00 | 1 | - | sd | 1,2,3,4 | ulg | - | - | - | - | ||||||||||||||||||||||||
| 66 | get | vwxcal | BrineTempInput | Kalibrierung Quelle Eintritt | MS | 08 | B509 | 3 | 0DCD00 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 67 | get | vwxcal | BrineTempOutput | Kalibrierung Quelle Austritt | MS | 08 | B509 | 3 | 0DC900 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 68 | get | vwxcal | CompressorTempInput | Kalibrierung Kompressor Eintritt | MS | 08 | B509 | 3 | 0DC600 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 69 | get | vwxcal | CompressorTempOutput | Kalibrierung Kompressor Austritt | MS | 08 | B509 | 3 | 0DC700 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 70 | get | vwxcal | FlowTemp | Kalibrierung Vorlauftemperatur VF1 | MS | 08 | B509 | 3 | 0DCA00 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 71 | get | vwxcal | FlowTempVF2 | Kalibrierung VF2 Temperatur | MS | 08 | B509 | 3 | 0DC500 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 72 | get | vwxcal | HotWaterTemp | Kalibrierung Warmwassertemperatur | MS | 08 | B509 | 3 | 0DC400 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 73 | get | vwxcal | OutsideTemp | Kalibrierung Aussentemperatur | MS | 08 | B509 | 3 | 0DC300 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 74 | get | vwxcal | ReturnTemp | Kalibrierung Rücklauftemperatur RF1 | MS | 08 | B509 | 3 | 0DCB00 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 75 | get | vwxcal | TankTempBottom | Kalibrierung Speicher Bodentemperatur | MS | 08 | B509 | 3 | 0D3401 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 76 | get | vwxcal | TankTempTop | Kalibrierung Speicher Kopftemperatur | MS | 08 | B509 | 3 | 0D3301 | 1 | - | sd | 1,2 | d2c | 1.0 | K | - | - | ||||||||||||||||||||||||
| 77 | get | vwxeh | CommutationState | Zusatzheizung Kommunikationsstatus | MS | 08 | B509 | 3 | 0DB100 | 1 | - | sd | 1,2,3,4 | ulg | - | - | - | - | ||||||||||||||||||||||||
| 78 | get | vwxeh | ElectricHeaterModeHeat | Zusatzheizung für Warmwasser | MS | 08 | B509 | 3 | 0D6300 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 79 | get | vwxeh | ElectricHeaterModeHotWater | Zusatzheizung für Heizung | MS | 08 | B509 | 3 | 0D6400 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 80 | get | vwxeh | ElectricHeaterState | Zusatzheizung Status | MS | 08 | B509 | 3 | 0D5F00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 81 | get | vwxeh | ElectricHeaterType | Zusatzheizung Typ | MS | 08 | B509 | 3 | 0D9200 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 82 | get | vwxeh | Hysteresis | Zusatzheizung Hysterese | MS | 08 | B509 | 3 | 0D7E00 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 83 | get | vwxeh | IntegralStartValue | Zusatzheizung Energieintegral Startwert | MS | 08 | B509 | 3 | 0D7F00 | 1 | - | sd | 1,2 | sin | - | °min | - | - | ||||||||||||||||||||||||
| 84 | get | vwxeh | RunTime | Zusatzheizung Laufzeit Summe | MS | 08 | B509 | 3 | 0DA100 | 1 | - | sd | 1,2,3,4 | ulg | - | h | - | - | ||||||||||||||||||||||||
| 85 | get | vwxeh | RunTimeHeating | Zusatzheizung Laufzeit Heizung | MS | 08 | B509 | 3 | 0DA200 | 1 | - | sd | 1,2,3,4 | ulg | - | h | - | - | ||||||||||||||||||||||||
| 86 | get | vwxeh | RunTimeHotWater | Zusatzheizung Laufzeit Warmwasser | MS | 08 | B509 | 3 | 0DA300 | 1 | - | sd | 1,2,3,4 | ulg | - | h | - | - | ||||||||||||||||||||||||
| 87 | get | vwxhw | FlowTemp | VF1 Bufferspeicher Kopftemperatur | MS | 08 | B509 | 3 | 0D0100 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 88 | get | vwxhw | HotWaterTempMax | Warmwasser Termperatur MAX | MS | 25 | B509 | 3 | 0D8200 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 89 | get | vwxhw | HotWaterTempMin | Warmwasser Termperatur MIN | MS | 25 | B509 | 3 | 0D8300 | 1 | - | sd | 1,2 | d2c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 90 | get | vwxhw | LegionellaProtectionActive | Legionellenfunktion aktivert | MS | 25 | B509 | 3 | 0D4000 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 91 | get | vwxhw | LegionellaProtectionDay | Legionellenfunktion Wochentag | MS | 25 | B509 | 3 | 0D7C01 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 92 | get | vwxhw | LegionellaProtectionTime | Legionellenfunktion Zeitpunkt | MS | 25 | B509 | 3 | 0D6700 | 2 | hh | sd | 1 | uch | - | h | - | Stunde | mm | sd | 2 | uch | - | min | - | Minute | ||||||||||||||||
| 93 | get | vwxhw | OperatingMode | Betriebsart | MS | 25 | B509 | 3 | 0D2B00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 94 | get | vwxhw | ReturnTemp | RF1 Bufferspeicher Bodentemperatur | MS | 08 | B509 | 3 | 0D0700 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 95 | get | vwxhw | TankTemp | Speichertemperatur IST | MS | 08 | B509 | 3 | 0D0000 | 2 | temp | sd | 1,2 | d2c | 1.0 | °C | - | Temperatur | sensor | sd | 3 | uch | - | - | - | Fühler | ||||||||||||||||
| 96 | get | vwxhw | TankTypePipe | Speichertyp ist Rohr | MS | 25 | B509 | 3 | 0DCD01 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 97 | get | vwxmk | CoolingOperatingMode | Kühlung Betriebsart | MS | 50 | B509 | 3 | 0D8C01 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 98 | get | vwxmk | DesiredTemp | Solltemperatur | MS | 50 | B509 | 3 | 0D3200 | 1 | - | sd | 1 | d1c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 99 | get | vwxmk | DesiredTempLow | Absenktemperatur | MS | 50 | B509 | 3 | 0D3300 | 1 | - | sd | 1 | d1c | 1.0 | °C | - | - | ||||||||||||||||||||||||
| 100 | get | vwxmk | FloorProtectionTempLimit | Fußbodenschutz Temp > VF2 | MS | 50 | B509 | 3 | 0D7B01 | 1 | - | sd | 1 | uch | - | °C | - | - | ||||||||||||||||||||||||
| 101 | get | vwxmk | FloorScreedDryingDay | Estrichtrocknung Tag | MS | 50 | B509 | 3 | 0D3B00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 102 | get | vwxmk | FlowTempDesired | Vorlauftemperatur Soll | MS | 50 | B509 | 3 | 0D4600 | 1 | - | sd | 1 | d1c | 1.0 | - | - | - | ||||||||||||||||||||||||
| 103 | get | vwxmk | HeatingCircuitType | Heizkreistyp | MS | 50 | B509 | 3 | 0D3C00 | 1 | - | sd | 1,2 | sin | - | - | - | - | ||||||||||||||||||||||||
| 104 | get | vwxmk | HeatingCurve | Heizkurve | MS | 50 | B509 | 3 | 0D3500 | 1 | - | sd | 1,2 | uin | - | - | - | - | ||||||||||||||||||||||||
| 105 | get | vwxmk | OperatingMode | Betriebsart | MS | 50 | B509 | 3 | 0D2B00 | 1 | - | sd | 1 | uch | - | - | - | - | ||||||||||||||||||||||||
| 106 | get | vwxmk | OutsideTempLimitShutdown | Abschaltgrenze Aussentempertur | MS | 50 | B509 | 3 | 0D3600 | 1 | - | sd | 1 | uch | - | °C | - | - | ||||||||||||||||||||||||
| 107 | get | vwxmk | PreHeatingTimeMax | Voraufheizung MAX | MS | 50 | B509 | 3 | 0D3800 | 1 | - | sd | 1 | uch | - | h | - | - | ||||||||||||||||||||||||
| 108 | get | vwxmk | PumpPower | Pumpen Leistung | MS | 50 | B509 | 3 | 0DBA01 | 1 | - | sd | 1 | uch | - | % | - | - | ||||||||||||||||||||||||
| 109 | get | vwxmk | PumpState | Pumpen Status | MS | 50 | B509 | 3 | 0DB901 | 1 | - | sd | 1 | uch | - | - | - | - |