Add missing 2 byte BCD time type
This is at least used by newer Vaillant models (VRC700, VR70, VR900).
This commit is contained in:
@@ -51,6 +51,7 @@ static const dataType_t dataTypes[] = {
|
|||||||
{"BTI", 24, bt_tim, BCD|REV|REQ, 0, 8, 8, 0}, // time in BCD, 00:00:00 - 23:59:59 (0x00,0x00,0x00 - 0x59,0x59,0x23)
|
{"BTI", 24, bt_tim, BCD|REV|REQ, 0, 8, 8, 0}, // time in BCD, 00:00:00 - 23:59:59 (0x00,0x00,0x00 - 0x59,0x59,0x23)
|
||||||
{"HTI", 24, bt_tim, REQ, 0, 8, 8, 0}, // time, 00:00:00 - 23:59:59 (0x00,0x00,0x00 - 0x17,0x3b,0x3b)
|
{"HTI", 24, bt_tim, REQ, 0, 8, 8, 0}, // time, 00:00:00 - 23:59:59 (0x00,0x00,0x00 - 0x17,0x3b,0x3b)
|
||||||
{"VTI", 24, bt_tim, REV, 0x63, 8, 8, 0}, // time, 00:00:00 - 23:59:59 (0x00,0x00,0x00 - 0x3b,0x3b,0x17, replacement 0x63) [Vaillant type]
|
{"VTI", 24, bt_tim, REV, 0x63, 8, 8, 0}, // time, 00:00:00 - 23:59:59 (0x00,0x00,0x00 - 0x3b,0x3b,0x17, replacement 0x63) [Vaillant type]
|
||||||
|
{"BTM", 16, bt_tim, BCD|REV, 0xff, 5, 5, 0}, // time in BCD, 00:00 - 23:59 (0x00,0x00 - 0x59,0x23, replacement 0xff) [Vaillant type]
|
||||||
{"HTM", 16, bt_tim, REQ, 0, 5, 5, 0}, // time as hh:mm, 00:00 - 23:59 (0x00,0x00 - 0x17,0x3b)
|
{"HTM", 16, bt_tim, REQ, 0, 5, 5, 0}, // time as hh:mm, 00:00 - 23:59 (0x00,0x00 - 0x17,0x3b)
|
||||||
{"VTM", 16, bt_tim, REV, 0xff, 5, 5, 0}, // time as hh:mm, 00:00 - 23:59 (0x00,0x00 - 0x3b,0x17, replacement 0xff) [Vaillant type]
|
{"VTM", 16, bt_tim, REV, 0xff, 5, 5, 0}, // time as hh:mm, 00:00 - 23:59 (0x00,0x00 - 0x3b,0x17, replacement 0xff) [Vaillant type]
|
||||||
{"TTM", 8, bt_tim, 0, 0x90, 5, 5, 10}, // truncated time (only multiple of 10 minutes), 00:00 - 24:00 (minutes div 10 + hour * 6 as integer)
|
{"TTM", 8, bt_tim, 0, 0x90, 5, 5, 10}, // truncated time (only multiple of 10 minutes), 00:00 - 24:00 (minutes div 10 + hour * 6 as integer)
|
||||||
|
|||||||